Product introduction
1.5t/h MVR evaporator composition
1.5t/h MVR evaporator is composed of evaporator, separator, compressor, vacuum pump, circulating pump, operating platform, electrical instrument control cabinet and valves, pipelines and other systems.
1.5t/h MVR evaporator features
1. High efficiency and energy saving: The use of mechanical steam recompression technology significantly reduces energy consumption and improves heat utilization.
2. Compact design: Small footprint, easy to install and maintain, suitable for limited space places.
3. Environmental performance: Achieve zero discharge and resource utilization of wastewater to reduce the burden on the environment.
4. Automatic operation: equipped with intelligent control system, simplify operation process and reduce labor cost.
1.5t/h MVR evaporator applications
1.5t/h MVR evaporators are widely used in many industrial fields, especially in industries requiring energy-efficient evaporation, crystallization and concentration processes. Specific application areas include:
1. Chemical industry: In the chemical production process, it is often necessary to concentrate the solution or extract the pure solvent, MVR evaporator technology can effectively complete these processes, while greatly reducing energy consumption.
2. Environmental protection: For high-salt wastewater treatment, landfill leachate treatment and other environmental management problems, MVR evaporator technology provides an effective solution. It can help reduce pollutant emissions and make emissions meet relevant environmental standards.
3. New energy industry: In some production processes in the field of new energy, such as battery manufacturing, evaporation technology also needs to be used to recover or purify substances.
4. Food industry: In the process of food processing, MVR evaporator can be used to concentrate juice, syrup and other liquid food, improve product concentration while retaining the original flavor.
5. Coal chemical industry: the wastewater produced by coal chemical industry contains a variety of chemical substances, and MVR evaporator technology can effectively treat and recycle wastewater.
6. Power industry: For example, in the treatment of desulfurization wastewater from power plants, MVR evaporators help to reduce treatment costs and improve the recycling rate of water resources.
7. Electroplating industry: The wastewater generated in the electroplating process contains harmful substances such as heavy metals, and MVR evaporator technology can be used for the purification and recycling of these harmful wastes.
Technical principle of
MVR evaporator technical principle for heavy metal sewage:
In the working process of MVR evaporator for heavy metal waste water, the first time sewage is heated to the boiling point by pre-heater. Then it is taken to the body of the evaporator and boiled in it to produce steam, while the heavy metal ions in the sewage water are concentrate. The results steam gets into liquid aerator, separation of pure vapor and concentrated liquid. Pure steam to the return of the evaporator as the heat source after strengthening by the vapor compressor, while the concentrate is further processed or recalled by the exhaust system.
The production process of
Production of equipment
Wteya aims to digital and intelligent production to provide superior products and services to its customers. We not only provide a wide range of standard products which are seriously tested and stable performance to meet a wide range of industrial needs. We also provide custom service, as well as OEM and ODM services, professional design team provides proper solutions for customers to meet their unique needs. We will work closely with each customer to ensure that every device suits customer's process requirements and production process accurately. Wteya's one-stop service, innovative to create high-quality mechanical products and system solutions, professionally help customer deal with various water treatment problems.
Capacity and size
MVR system parameter board |
|||||
Evaporator (T/h) |
Evaporative way to make |
Total energy (kW/h) |
Steam consumption (T/h) |
Reuse water consumption (t/h) |
Area of the (length, height/m) |
0.5 |
MVR, loop required |
70 |
0-0.03 |
10 |
6*3*5 |
1 |
MVR, loop required |
110 |
0-0.05 |
10 |
9*8*6 |
1.5 |
MVR, loop required |
180 |
0-0.05 |
20 |
12*7.5*9 |
2 |
MVR, loop required |
213.5 |
0-0.1 |
30 |
12*8*10 |
3 |
MVR, loop required |
275 |
0-0.1 |
50 |
15*8*15 |
5 |
MVR, loop required |
425 |
0-0.2 |
50 |
15*10*15 |
7.5 |
MVR, loop required |
580 |
0-0.3 |
70 |
15*12*15 |
10 |
MVR, loop required |
815 |
0-0.3 |
100 |
12*6*18 |
Temperature panel parameters |
|||||
Evaporator (T/h) |
Heat exchanger type |
Specification (specification) |
The material is material |
Qty of the quantity |
Used to have |
0.5 |
Two horizontal pipe, Circulation required round |
S = 50m ², galls 500 × 6000 × 5mm |
TA2 |
1 |
|
1 |
Two horizontal pipe, Circulation required round |
S = 100m ², Nils 650 × 6000 × 5mm |
TA2 |
1 |
|
1.5 |
Two horizontal pipe, Circulation required round |
S = 150m ², galls 800 × 6000 × 5mm |
TA2 |
1 |
|
2 |
Two horizontal pipe, Circulation required round |
S = 200m ², Nils 800 × 5mm |
TA2 |
1 |
|
3 |
Two horizontal pipe, Circulation required round |
S = 260m ², galls 1000 × 6000 × 5mm |
TA2 |
1 |
|
5 |
Two horizontal pipe, Circulation required round |
S = 450m ², Nils 1300 × 6000 × 6mm |
TA2 |
1 |
|
7.5 |
Two horizontal pipe, Circulation required round |
S = 650m ², Nils 1500 × 6000 × 6mm |
TA2 |
1 |
|
10 |
Two horizontal pipe, Circulation required round |
S = 880m ², Nils 1800 × 6000 × 8mm |
TA2 |
1 |
|
Chart of effect chart
Frequently Asked Questions
Q: MVR forced evaporator to run?
Cause: could be the corrosion of secondary steam pipes or air compressors, pure water quality does not meet the standards, or at the point of equipment such as welding, flange, sealing, expansion, and so on.
Solution: ensure water quality into standards, regularly cleaning the system, maintain stable cooling water temperature, and provide a complete amount of cooling water.
Problem: MVR is required to deflate slow feeding or a small flow situation?
Reason: usually due to the filter is blocked.
Solution: inspection and purification of filters.
Q: The steam reduction charged by MVR?
Cause: could be due to system clogging or dirt in the hot water catheter.
Solution: do online purification programs for cleaning dirt.
Q: The effect of steam valve charged by MVR?
Cause: The material is processed after thickening, crystally, resulting in clogging.
Solution: The Prevention includes regular filter of salt and spray as well, once stuck, use juice or vacuum treatment.
Q: MVR compulsory evaporator effect?
Expression: Produces regular and loud sound, vibrates the pipes.
Solution: constant current stability compressor when counter rate is soft and open the valve through the appropriate rate; counter rate need to close the compressor immediately for testing, pay attention to liquid temperature to avoid counter rate.
Q: cool MVR evaporator don't work properly?
Cause: could be due to too thick dust, or vacuum drop.
Solution: add agent foaming agent, check detector and dehumidifying liquid, import steam valve adjustment, vacuum control.
Q: MVR is required to circulation irregular level of steam separator?
Cause of the high level: too many data feed, Crystal pump fault or export focus clogging.
Solution: reduce the amount of data input, check the pump, open the drainage pipe.
Cause of the low level: too small or leaking of the concentration tube.
Solution: increase the amount of data input, check the drainage pipe.
S/N | Single effect evaporator | Multi effect evaporator | TVR evaporator | MVR evaporator |
---|---|---|---|---|
Energy source | Using steam heating Steam pipe network Need boiler |
Using steam heating Steam pipe network Need boiler |
Need high pressure steam to drive, Need boiler |
Using electric power, no need steam pipe network close loop circulation system |
Energy consumption | 1 tons steam for 1ton water evaporation | 0.3~1tons steam for 1ton water evaporation | Based on traditional multi effect, one more effect is used with high pressure steam drive | The most energy saving technology at present |
Operation cost | Much higher | More energy saving | Lower | Lowest |
Footprint | smaller | bigger | bigger | smaller |
Product quality | Short residence time, Bigger temp. difference lead to easy scale. product quality not stable |
Longer residence time, Bigger temp. difference lead to easy scale. product quality not stable |
Short residence time, Smaller influence on product quality |
Short residence time, Low temp. evaporation, Minimum impact on product quality |
Control type | Semi-automatic | Full automatic Uninterrupted evaporation |
Full automatic Uninterrupted evaporation |