en
MVR Evaporator
MVR Evaporator

Advanced Waste Water MVR Evaporator

Brand: WTEYA GROUP
MOQ: 1 Pieces
Delivery time: 15 Day
MVR evaporator for heavy metal waste water is a high efficiency evaporator designed for heavy metal industrial sewage, using mechanical bubble recompression (MVR) technology, to achieve the concentration and filtration of waste water.
Product Details

Product introduction

 

Heavy metal exhaust water features: Heavy metal exhaust water mention industrial sewage containing harmful metal ions such as copper, lead, zinc, cadmium. This type of sewage if not directly treated, it will be a great risk to human health and environment. Its features include:


1. strong detox: heavy metal ions provide high detox to the human body and ecoenvironment.

2. difficult to biodegradable: Heavy metals are not easy to be biodegraded, easily stored in the food chain.

3. long residue: long lasting of heavy metal in the environment, broad impact.

4. difficult treatment: traditional chemical chroma could not completely remove heavy metal ions from sewage.

 

 

MVR evaporator introduction for heavy metal waste water:

 

MVR evaporator for heavy metal waste water is a high efficiency evaporator designed for heavy metal industrial sewage, using mechanical bubble recompression (MVR) technology, to achieve the concentration and filtration of waste water.

 

 

MVR evaporator component for heavy metal waste water:

 

This device is mainly made up of preheating element, evaporator body, liquid gas separator, steam compressor, and core parts such as condenser. They work together to complete an effective evaporator for heavy metal waste water.

 

 

MVR evaporator for heavy metal waste water advantages:

 

High efficiency and energy saving: vapor compression technology greatly reduces external energy needs and saves energy consumption.

Environmental Performance: no additional chemicals are required during processing, reduces the ability to secondary pollution.

High automation level: equipped with PLC control system to achieve high automation operation and reduce labor cost.

High application ability: can deal with heavy metal waste water with different ingredients and concentration, with good adaptation.

Considerable economic benefits: while saving energy, it also restores value metal resources from waste water and increasing economic benefits.

 

 

MVR evaporator application areas for heavy metal sewage:

This equipment is widely used in electroplate, electronic, metallurgy, chemical and other industries, particularly suitable for the treatment of industrial sewage with heavy metal ions.

 

 

Technical principle of

 

MVR evaporator technical principle for heavy metal sewage:

In the working process of MVR evaporator for heavy metal waste water, the first time sewage is heated to the boiling point by pre-heater. Then it is taken to the body of the evaporator and boiled in it to produce steam, while the heavy metal ions in the sewage water are concentrate. The results steam gets into liquid aerator, separation of pure vapor and concentrated liquid. Pure steam to the return of the evaporator as the heat source after strengthening by the vapor compressor, while the concentrate is further processed or recalled by the exhaust system.

 

 

The production process of

 

xx

 

Production of equipment

 

xx

 

Wteya aims to digital and intelligent production to provide superior products and services to its customers. We not only provide a wide range of standard products which are seriously tested and stable performance to meet a wide range of industrial needs. We also provide custom service, as well as OEM and ODM services, professional design team provides proper solutions for customers to meet their unique needs. We will work closely with each customer to ensure that every device suits customer's process requirements and production process accurately. Wteya's one-stop service, innovative to create high-quality mechanical products and system solutions, professionally help customer deal with various water treatment problems.

 

 

Capacity and size

 

MVR system parameter board

Evaporator (T/h)

Evaporative way to make

Total energy (kW/h)

Steam consumption (T/h)

Reuse water consumption (T/h)

Area of the (length, height/m)

0.5

MVR, loop required

70

0-0.03

10

6*3*5

1

MVR, loop required

110

0-0.05

10

9*8*6

1.5

MVR, loop required

180

0-0.05

20

12*7.5*9

2

MVR, loop required

213.5

0-0.1

30

12*8*10

3

MVR, loop required

275

0-0.1

50

15*8*15

5

MVR, loop required

425

0-0.2

50

15*10*15

7.5

MVR, loop required

580

0-0.3

70

15*12*15

10

MVR, loop required

815

0-0.3

100

12*6*18

 

Temperature panel parameters

Evaporator (T/h)

Heat exchanger type

Specification (specification)

The material is material

Qty of the quantity

Used to have

0.5

Two horizontal pipe,

Circulation required round

S = 50m ², galls 500 × 6000 × 5mm

TA2

1

 

1

Two horizontal pipe,

Circulation required round

S = 100m ², Nils 650 × 6000 × 5mm

TA2

1

 

1.5

Two horizontal pipe,

Circulation required round

S = 150m ², galls 800 × 6000 × 5mm

TA2

1

 

2

Two horizontal pipe,

Circulation required round

S = 200m ², Nils 800 × 5mm

TA2

1

 

3

Two horizontal pipe,

Circulation required round

S = 260m ², galls 1000 × 6000 × 5mm

TA2

1

 

5

Two horizontal pipe,

Circulation required round

S = 450m ², Nils 1300 × 6000 × 6mm

TA2

1

 

7.5

Two horizontal pipe,

Circulation required round

S = 650m ², Nils 1500 × 6000 × 6mm

TA2

1

 

10

Two horizontal pipe,

Circulation required round

S = 880m ², Nils 1800 × 6000 × 8mm

TA2

1

 

 

 

Chart of effect chart

xx

 

Frequently Asked Questions

 

Q: MVR forced evaporator to run?

Cause: could be the corrosion of secondary steam pipes or steam compressors, pure water quality does not meet the standards, or at the point of equipment such as welding, flange, sealing, expansion, and so on.

Solution: ensure water quality into standards, regularly cleaning the system, maintain stable cooling water temperature, and provide a complete amount of cooling water.

 

Q: The steam reduction charged by MVR?

Cause: could be due to system clogging or dirt in the hot water catheter.

Solution: do online purification programs for cleaning dirt.

 

Q: The effect of steam valve charged by MVR?

Cause: The material is processed after thickening, crystally, resulting in clogging.

Solution: The Prevention includes regular filter of salt and spray as well, once stuck, use juice or vacuum treatment.

 

Q: MVR compulsory evaporator effect?

Expression: Produces regular and loud sound, vibrates the pipes.

Solution: constant current stability compressor when counter rate is soft and open the valve through the appropriate rate; counter rate need to close the compressor immediately for testing, pay attention to liquid temperature to avoid counter rate.

 

Q: cool MVR evaporator don't work properly?

Cause: could be due to too thick dust, or vacuum drop.

Solution: add agent foaming agent, check detector and dehumidifying liquid, import steam valve adjustment, vacuum control.

 

 

S/N Single effect evaporator Multi effect evaporator TVR evaporator MVR evaporator
Energy source Using steam heating
Steam pipe network
Need boiler
Using steam heating
Steam pipe network
Need boiler
Need high pressure steam to drive,
Need boiler
Using electric power,
no need steam pipe network
close loop circulation system
Energy consumption 1 tons steam for 1ton water evaporation 0.3~1tons steam for 1ton water evaporation Based on traditional multi effect, one more effect is used with high pressure steam drive The most energy saving technology at present
Operation cost Much higher More energy saving Lower Lowest
Footprint smaller bigger bigger smaller
Product quality Short residence time,
Bigger temp. difference lead to easy scale.
product quality not stable
Longer residence time,
Bigger temp. difference lead to easy scale.
product quality not stable
Short residence time,
Smaller influence on product quality
Short residence time,
Low temp. evaporation,
Minimum impact on product quality
Control type Semi-automatic Full automatic
Uninterrupted evaporation
Full automatic
Uninterrupted evaporation
Full automatic
Uninterrupted evaporation